Data Center infrastructure

Our Services

Data Center infrastructure

What is a Data Center

data center is a facility designed for continuous use by several users.

DC is well equipped with

  • Computer systems
  • Telecommunications and storage systems.

Generally, It includes:

  • power supplies,
  • data communications connections,
  • environmental controls (e.g., air conditioning, fire suppression) and security devices.
data center

Power System (UPS)

Power System ups

Raised Floor

40NF Panel:
  • 38mm-thick particle board core
  • Strengthened by high performance resins
  • Up to 650 Kilogram per cubic centimeter (high density)
  • Coated from both sides by different material
  • From the top the coating is antistatic hard plastic laminate for better isolation and liquid leak protection.
  • From the bottom is 0.5 mm galvanized steel for also isolation and high air circulation under the raised floor.
  • 40NF can carry up to 2000 Kilogram force per square meter
Perforated panel:
  • Steel perforated panel 60X60 CM 588 holes 13mm diameter each
  • Max flow rate/tile = 1200 cubic meter/hr
  • Pedestals (better cooling area, air circulation)
  • Medium stringers (UNI8)
  • Height of 60 cm.
  • Raised floor height = 45 cm (Tier II)
  • Floor loading Kg/m2 = 488 (Tier II)

Raised Floor Features

  • Control and Balance Data Center Airflow
  • Separate Hot Aisles from Cold Aisles
  • Reduces Energy Consumption and Operating Costs
  • Non-Conductive and Non-Hygroscopic Material
  • Flammability rating of UL94 V-0
  • No Installation Tools Required
  • On-Site Configurable (Width and Height)
  • Fits any Raised Floor Pedestal
data center Raised Floor
defining-liquid-cooling-in-the-data-center

Cooling

SENSORS

  • Return air temperature sensor
  • Humidity sensor
  • Tape liquid leak detector
  • Differential air pressure sensor (air filter and Fans)

Fire Alarm & Fighting

FM200 for DC – benefits

  • Colorless
  • Odorless
  • Electrically Non-Conductive
  • Require no Cleanup
  • Safe for people, fabrics, equipment, textiles, paint, photo media, etc.
  • Quick extinguishing
  • Concentration in 10 seconds
firesprinkler
access-control-systems

Access Control

Smart Card, Numeric, Bi-metric Readers

  • Smart Card Reader
    • 13.56 MHz Readers – Secure Sector
    • Wiegand Output
    • Secure Sector Reader
  • Fingerprint Reader
    • Secure Sector Reader
    •  1 to 1 Matching template to live scan
    • Secure Sector for Template Storage
    •  Keypad
    • 12 VDC Reader
    •  Wiegand and RS-485 outputs

Video Surveillance (CCTV)

 

 
 

Basic CCTV system example

 

 
 

Pathway system

 

 
 

Pathway under Raised floor

 