Product overview
This inert-gas system suppresses fire by reducing oxygen concentration within the protected enclosure. Regulated discharge helps control downstream pressure and supports a distribution arrangement with smaller pipework than conventional orifice systems. Selector valves allow the designer to consider several protected enclosures served by one container bank.
Technical specifications
| Manufacturer | ANSUL |
|---|---|
| Product / system | iFLOW 300 Bar System |
| Product type | Fire Suppression |
| Product family | Gaseous Suppression |
| Subcategory | Inert Gas |
| Agent options | IG-541 (INERGEN), IG-55 or IG-100 |
| System pressure designation | 300 bar |
| Discharge control | Regulated inert-gas flow |
| Multiple enclosures | Selector-valve configurations available |
| Container arrangement | Matrix bracket system for 80 L containers |
| Manufacturer-listed approvals | UL Listed; FM Approved; VdS system approval; A2P system approval; CNBOP system listing; CE component approval; PESO component approval |
Approval scope applies to the listed system and component configuration. Confirm the selected equipment against the current manufacturer document and project submittal.
Key features
- Regulated discharge supports efficient pipe and vent design
- Selector valves enable multi-enclosure arrangements
- Acoustic nozzle options address sound-sensitive applications
Applications
Sensitive equipment enclosures, including server rooms and data center spaces, where the system design and personnel safeguards permit inert-gas protection.
Selection and project integration
Share the protected-space drawings, hazard description, equipment schedule and project specification with UDCT. The technical review should establish the selected system configuration, required quantity, installation constraints and interfaces with the detection and control equipment. For gaseous suppression, enclosure integrity, pressure relief, discharge acoustics and personnel safeguards must be assessed as part of the engineered design.
The published model designation is a product reference, not a final bill of materials. Agent quantities, pipe sizing, nozzle selection, storage arrangements and release logic depend on the approved design. Use the current manufacturer instructions for installation, testing and maintenance, and confirm availability with UDCT before procurement.
Manufacturer documents
- F-2016332-02-CFR ( French-Canada ) (opens in a new tab)
- ANSUL INERGEN Clean Agent Fire Suppression System with iFLOW Technology Engineering Specifications ( English ) (opens in a new tab)
- ANSUL INERGEN Clean Agent Fire Suppression System with iFLOW Technology and AUTOPULSE Z-20 Agent Releasing Control Panel Specifications (Canadian French) ( French-Canada ) (opens in a new tab)
- INERGEN 300 Bar Fire Suppression System with iFLOW Technology ( English ) (opens in a new tab)
- ANSUL INERGEN System with iFLOW Technology Product Overview ( English ) (opens in a new tab)
- F-200045-05 INERGEN Extinguishing Agent ( English ) (opens in a new tab)
Official product reference
View this product on the manufacturer website (opens in a new tab)