Product overview
CHEMGUARD VARI-X-III is a portable adjustable-expansion foam nozzle with a matching eductor and inlet pressure gauge. A large selector knob provides discrete low-, medium- and high-expansion settings. Each setting has its own concentration, inlet pressure and documented throw range, so the chosen setting must be treated as a complete operating combination. The published ranges describe manufacturer test conditions and do not establish a guaranteed coverage envelope at every site. Select the appropriate compatible concentrate, inlet coupling and water supply, and confirm the current model revision before specification.
Technical specifications
| Brand / product range | CHEMGUARD |
|---|---|
| Product / system | Vari-X-III High Expansion Handline Nozzle |
| Product type | Foam Systems |
| Product family | Foam Discharge Equipment |
| Subcategory | Nozzles / Monitors / Eductors |
| Product | VARI-X-III adjustable-expansion portable foam nozzle |
| NH-thread model | EF10572 |
| NPSH-thread model | EF10573 |
| Inlet | 1½ inch; selected NH or NPSH thread |
| Body | Steel with fused vinyl powder coating |
| Controls | Pistol-grip shutoff; click-stop expansion selector |
| Pressure indication | Inlet pressure gauge |
| Low-expansion setting | 6% at 100 psi; documented throw 40–50 feet |
| Medium-expansion setting | 3% at 90 psi; documented throw 30–35 feet |
| High-expansion setting | 2% at 80 psi; documented throw 10–12 feet |
| Eductor | Matching eductor in the documented assembly |
| Operating scope | Keep concentration, pressure and expansion setting paired; actual throw depends on conditions |
| Document revision | Shared 2008 MINI-X-III / VARI-X-III technical sheet; confirm current availability |
Key features
- Product: VARI-X-III adjustable-expansion portable foam nozzle
- NH-thread model: EF10572
- NPSH-thread model: EF10573
Applications
Selected portable foam response for spill-fire control and vapour mitigation using an appropriate agent. Confirm the hazard, required expansion mode, water duty and deployment conditions before selecting the operating setting.
Selection and project integration
Provide UDCT with the fuel or test application, required capacity, available water pressure and flow, selected concentrate and compatible equipment. Confirm the exact part numbers, coupling threads, storage conditions and current manufacturer instructions. For foam systems, use the fuel-specific application criteria and approved proportioning/discharge assembly; commissioning must verify the actual hydraulic and proportioning performance.
Manufacturer documents
Official product reference