HD FIRE PROTECT AFFF 3-C6 & AFFF 3F-C6

HD AFFF 3-C6 and AFFF 3F-C6 are aqueous film-forming foam concentrates for hydrocarbon fire protection.

HD FIRE PROTECT AFFF 3-C6 & AFFF 3F-C6 — manufacturer system image
Manufacturer concentrate image. The selected 3-C6 or 3F-C6 formulation and its approval scope must be confirmed with the quotation.

Product overview

HD AFFF 3-C6 and AFFF 3F-C6 are aqueous film-forming foam concentrates for hydrocarbon fire protection. The manufacturer specifies a 3% solution with compatible water and foam equipment. The selected concentrate, proportioner and discharge device must be checked as a complete system. The 3-C6 and 3F-C6 variants have separately scoped approvals and physical-property test temperatures, identified in the table below.

Technical specifications

Manufacturer HD FIRE PROTECT
Product / system AFFF 3-C6 & AFFF 3F-C6
Product type Foam Systems
Product family Foam Concentrates
Subcategory Foam Concentrates
Concentrate type Aqueous film-forming foam (AFFF), C6 formulation
Mixing ratio 3%
Water compatibility Fresh / sea-salt / hard water
3-C6 approval scope UL Listed to UL 162
3F-C6 approval scope UL Listed and FM Approved; exact foam-system configuration applies
3-C6 specific gravity at 20°C 1.02 ± 0.02
3-C6 pH at 20°C 8.0 ± 1.0
3-C6 viscosity at 20°C Less than 2 cSt
3F-C6 specific gravity at 25°C 1.02 ± 0.02
3F-C6 pH at 25°C 8.0 ± 1.0
3F-C6 viscosity at 25°C Less than 3 cSt
Pour point Flows at −2°C; freeze-protected types separately selected
Packaging options 20-litre cans / 200-litre drums / 1,000-litre totes / bulk

Key features

  • Concentrate type: Aqueous film-forming foam (AFFF), C6 formulation
  • Mixing ratio: 3%
  • Water compatibility: Fresh / sea-salt / hard water

Applications

Class B hydrocarbon hazards such as fuel storage, process areas, refineries, terminals and aviation-fuel facilities within the approved application scope.

Selection and project integration

Share the system drawings, protected hazard, equipment schedule and project specification with UDCT. Product selection should establish the required flow and pressure, pipework connections, materials, installation orientation and compatible components. Check the precise approval scope for the selected model, size and configuration against the current manufacturer documentation.

The product reference does not replace hydraulic calculations or the approved system design. For foam equipment, confirm the concentrate, proportioning range and discharge-device compatibility as one system. Use the manufacturer instructions for installation, commissioning and maintenance, and confirm the supplied configuration with UDCT before procurement.

Manufacturer documents

Official product reference

View this product on the manufacturer website (opens in a new tab)

START A PROJECT

Discuss this product with UDCT

Send your project specification and required quantities for technical selection and supply support.