Product overview
HD Hazmat Foam HF is formulated to create a foam blanket for suppressing hazardous vapour release from compatible chemical spills. The HF 1, HF 2 and HF 3 variants address different chemical conditions, so selection depends on the specific substance and the manufacturer compatibility guidance. It is a vapour-suppression product and should be selected within the site emergency-response plan.
Technical specifications
| Manufacturer | HD FIRE PROTECT |
|---|---|
| Product / system | Hazmat Foam HF |
| Product type | Foam Systems |
| Product family | Foam Concentrates |
| Subcategory | Foam Concentrates |
| Product duty | Hazardous-vapour suppression foam |
| Solution choices | 3% / 6% in fresh water |
| HD HF 1 duty | Alkaline chemical spills within documented compatibility scope |
| HD HF 2 duty | Acidic chemical spills within documented compatibility scope |
| HD HF 3 duty | Neutral chemical applications listed in the manufacturer sheet |
| Specific gravity at 20°C | 1.00–1.10 for HF 1 / HF 2 / HF 3 |
| HF 1 pH at 20°C | 7.5–8.5 |
| HF 2 pH at 20°C | 4.5–5.5 |
| HF 3 pH at 20°C | 6.5–8.5 |
| HF 1 / HF 2 viscosity at 20°C | At most 10 cSt |
| HF 3 viscosity at 20°C | At most 2,500 cSt |
| Packaging options | 20-litre cans / 200-litre drums / 1,000-litre totes / bulk |
Key features
- Product duty: Hazardous-vapour suppression foam
- Solution choices: 3% / 6% in fresh water
- HD HF 1 duty: Alkaline chemical spills within documented compatibility scope
Applications
Compatible chemical processing, storage, transfer and containment areas. Substance-specific suitability and the limitations in the manufacturer sheet must be assessed before selection.
Selection and project integration
Share the system drawings, protected hazard, equipment schedule and project specification with UDCT. Product selection should establish the required flow and pressure, pipework connections, materials, installation orientation and compatible components. Check the precise approval scope for the selected model, size and configuration against the current manufacturer documentation.
The product reference does not replace hydraulic calculations or the approved system design. For foam equipment, confirm the concentrate, proportioning range and discharge-device compatibility as one system. Use the manufacturer instructions for installation, commissioning and maintenance, and confirm the supplied configuration with UDCT before procurement.