HD FIRE PROTECT · Gaseous Suppression

HD FIRE PROTECT HD-INERTSYS Inert Gas System

HD-INERTSYS provides engineered inert-gas suppression using IG-55, IG-541, IG-100 or IG-01.

HD FIRE PROTECT HD-INERTSYS Inert Gas System — manufacturer system image
Manufacturer system image. Supplied configuration is defined by the approved product selection.

Product overview

HD-INERTSYS provides engineered inert-gas suppression using IG-55, IG-541, IG-100 or IG-01. The manufacturer lists 80- and 140-litre cylinder options with 200- or 300-bar storage, selected for the required concentration and volume. Selector or directional valves support the protection of multiple areas from a common cylinder bank. The design uses the specified VdS calculation method.

Technical specifications

Manufacturer HD FIRE PROTECT
Product / system HD-INERTSYS Inert Gas System
Product type Fire Suppression
Product family Gaseous Suppression
Subcategory Inert Gas
Agent options IG-55 / IG-541 / IG-100 / IG-01
IG-55 composition 50% argon / 50% nitrogen
IG-541 composition 52% nitrogen / 40% argon / 8% carbon dioxide
IG-100 agent Nitrogen
IG-01 agent Argon
Cylinder volumes 80 / 140 litres
Storage pressure options 200 / 300 bar
Release device options Manual / pneumatic / electromagnetic
Multi-area arrangement Selector / directional valves
Manufacturer-stated approval VdS

Key features

  • Agent options: IG-55 / IG-541 / IG-100 / IG-01
  • IG-55 composition: 50% argon / 50% nitrogen
  • IG-541 composition: 52% nitrogen / 40% argon / 8% carbon dioxide

Applications

Enclosed hazards selected for inert-gas protection. Confirm concentration, enclosure integrity, pressure relief and personnel safeguards in the engineered design.

Selection and project integration

Share the protected-space drawings, hazard description, equipment schedule and project specification with UDCT. The technical review should establish the selected system configuration, required quantity, installation constraints and interfaces with the detection and control equipment. For gaseous suppression, enclosure integrity, pressure relief, discharge acoustics and personnel safeguards must be assessed as part of the engineered design.

The published model designation is a product reference, not a final bill of materials. Agent quantities, pipe sizing, nozzle selection, storage arrangements and release logic depend on the approved design. Use the current manufacturer instructions for installation, testing and maintenance, and confirm availability with UDCT before procurement.