HYGOOD · Gaseous Suppression

HYGOOD Marine FM-200 25 Bar System

FM-200 25 Bar provides gaseous suppression using FM-200 agent for equipment and enclosed hazards where an electrically non-conductive medium is needed.

HYGOOD Marine FM-200 25 Bar System — manufacturer system image
Manufacturer system image. Supplied configuration is defined by the approved product selection.

Product overview

FM-200 25 Bar provides gaseous suppression using FM-200 agent for equipment and enclosed hazards where an electrically non-conductive medium is needed. The agent suppresses fire mainly through heat absorption. The marine configuration has its own approval scope and should be specified from the marine documentation.

Technical specifications

Manufacturer HYGOOD
Product / system Marine FM-200 25 Bar System
Product type Fire Suppression
Product family Gaseous Suppression
Subcategory Marine Suppression
Agent FM-200
System pressure designation 25 bar
Protection approach Gaseous suppression
Electrical characteristic Non-conductive extinguishing agent
Manufacturer-listed approvals Lloyd’s and DNV (manufacturer-listed marine scope)

Approval scope applies to the listed system and component configuration. Confirm the selected equipment against the current manufacturer document and project submittal.

Key features

  • Heat absorption provides the principal extinguishing action
  • Agent concentration must be maintained for the required protection period
  • The complete system requires application-specific engineering

Applications

Marine equipment spaces within the documented marine approval scope.

Selection and project integration

Share the protected-space drawings, hazard description, equipment schedule and project specification with UDCT. The technical review should establish the selected system configuration, required quantity, installation constraints and interfaces with the detection and control equipment. For gaseous suppression, enclosure integrity, pressure relief, discharge acoustics and personnel safeguards must be assessed as part of the engineered design.

The published model designation is a product reference, not a final bill of materials. Agent quantities, pipe sizing, nozzle selection, storage arrangements and release logic depend on the approved design. Use the current manufacturer instructions for installation, testing and maintenance, and confirm availability with UDCT before procurement.

Manufacturer documents

Official product reference

View this product on the manufacturer website (opens in a new tab)

START A PROJECT

Discuss this product with UDCT

Send your project specification and required quantities for technical selection and supply support.