HYGOOD Marine SAPPHIRE 25 Bar System

This 25 bar Sapphire system uses FK-5-1-12 for fire suppression around valuable equipment.

HYGOOD Marine SAPPHIRE 25 Bar System — manufacturer system image
Manufacturer system image. Supplied configuration is defined by the approved product selection.

Product overview

This 25 bar Sapphire system uses FK-5-1-12 for fire suppression around valuable equipment. Its non-conductive agent acts primarily by absorbing heat and avoids the residue associated with some other extinguishing media. The marine version is intended for shipboard applications and has a marine approval scope that differs from the land-based system.

Technical specifications

Manufacturer HYGOOD
Product / system Marine SAPPHIRE 25 Bar System
Product type Fire Suppression
Product family Gaseous Suppression
Subcategory Marine Suppression
Agent FK-5-1-12
System pressure designation 25 bar
Protection approach Gaseous clean agent
Electrical characteristic Non-conductive extinguishing agent
Manufacturer-listed approvals MED, MER, Lloyd’s, DNV, BV, RINA and ABS (manufacturer-listed marine scope)

Approval scope applies to the listed system and component configuration. Confirm the selected equipment against the current manufacturer document and project submittal.

Key features

  • Agent absorbs heat during suppression
  • Clean discharge limits residue cleanup
  • Engineered nozzle and pipe network

Applications

Shipboard spaces and marine equipment areas identified in the approved system design.

Selection and project integration

Share the protected-space drawings, hazard description, equipment schedule and project specification with UDCT. The technical review should establish the selected system configuration, required quantity, installation constraints and interfaces with the detection and control equipment. For gaseous suppression, enclosure integrity, pressure relief, discharge acoustics and personnel safeguards must be assessed as part of the engineered design.

The published model designation is a product reference, not a final bill of materials. Agent quantities, pipe sizing, nozzle selection, storage arrangements and release logic depend on the approved design. Use the current manufacturer instructions for installation, testing and maintenance, and confirm availability with UDCT before procurement.

Manufacturer documents

Official product reference

View this product on the manufacturer website (opens in a new tab)

START A PROJECT

Discuss this product with UDCT

Send your project specification and required quantities for technical selection and supply support.