CFT-01 uses IG-01, based on argon, for engineered fire suppression in enclosed hazards.

SIEX CFT-01 — manufacturer system image
Manufacturer system image. Supplied configuration is defined by the approved product selection.

Product overview

CFT-01 uses IG-01, based on argon, for engineered fire suppression in enclosed hazards. It reduces the oxygen concentration supporting combustion, so enclosure integrity, evacuation and personnel safeguards form part of the system design. The CFT configuration controls gas release during discharge. Its flow-control arrangement differs from a conventional pressure-restrictor system and requires the manufacturer calculation method.

Technical specifications

Manufacturer SIEX
Product / system CFT-01
Product type Fire Suppression
Product family Gaseous Suppression
Subcategory Inert Gas
Extinguishing agent IG-01
Agent composition Argon
Protection approach Engineered inert-gas suppression
Discharge technology Constant Flow Technology (CFT)
Flow-control valve RGS-MAM-RD

Key features

  • Non-conductive inert-gas agent
  • Residue-free extinguishing medium
  • Regulated flow during discharge

Applications

Data processing rooms, telecommunications facilities, archives, museums and electrical equipment areas within the approved system design.

Selection and project integration

Share the protected-space drawings, hazard description, equipment schedule and project specification with UDCT. The technical review should establish the selected system configuration, required quantity, installation constraints and interfaces with the detection and control equipment. For gaseous suppression, enclosure integrity, pressure relief, discharge acoustics and personnel safeguards must be assessed as part of the engineered design.

The published model designation is a product reference, not a final bill of materials. Agent quantities, pipe sizing, nozzle selection, storage arrangements and release logic depend on the approved design. Use the current manufacturer instructions for installation, testing and maintenance, and confirm availability with UDCT before procurement.

Manufacturer documents

Official product reference

View this product on the manufacturer website (opens in a new tab)

START A PROJECT

Discuss this product with UDCT

Send your project specification and required quantities for technical selection and supply support.