SIEX · CO2 Suppression

SIEX Fixed Hose Stations

SIEX Fixed Hose Stations provide manually applied carbon dioxide suppression from a fixed cylinder and hose-reel arrangement.

SIEX Fixed Hose Stations — manufacturer system image
Manufacturer system image. Supplied configuration is defined by the approved product selection.

Product overview

SIEX Fixed Hose Stations provide manually applied carbon dioxide suppression from a fixed cylinder and hose-reel arrangement. The manufacturer describes two 67-litre cylinders, a swing-out reel and a trigger-controlled discharge nozzle. The station is intended for local application around the identified equipment hazard and requires the appropriate operator training and site safeguards.

Technical specifications

Manufacturer SIEX
Product / system Fixed Hose Stations
Product type Fire Suppression
Product family CO2 Suppression
Subcategory CO2 Systems
Extinguishing agent Carbon dioxide (CO2)
Electrical characteristic Non-conductive agent
Residue No extinguishing residue
Cylinder arrangement Two 67-litre CO2 cylinders
Discharge control Manual application through trigger-controlled nozzle
Hose reel Swing-out arrangement

Key features

  • CO2 extinguishing medium
  • Equipment configuration selected for the hazard
  • Manufacturer documentation available

Applications

Industrial and equipment hazards within the approved CO2 system design. Carbon dioxide can create a dangerous atmosphere; personnel exclusion, evacuation, alarms and other required safeguards must be addressed in the engineered installation.

Selection and project integration

Share the protected-space drawings, hazard description, equipment schedule and project specification with UDCT. The technical review should establish the selected system configuration, required quantity, installation constraints and interfaces with the detection and control equipment. For gaseous suppression, enclosure integrity, pressure relief, discharge acoustics and personnel safeguards must be assessed as part of the engineered design.

The published model designation is a product reference, not a final bill of materials. Agent quantities, pipe sizing, nozzle selection, storage arrangements and release logic depend on the approved design. Use the current manufacturer instructions for installation, testing and maintenance, and confirm availability with UDCT before procurement.

Manufacturer documents

Official product reference

View this product on the manufacturer website (opens in a new tab)

START A PROJECT

Discuss this product with UDCT

Send your project specification and required quantities for technical selection and supply support.