Skip to content
SAUDI ARABIA  |  UAE  |  EGYPT
BUILT TO PROTECT ... ENGINEERED TO ENDURE+966122333155

SIEX · CO2 Suppression

SIEX Low Pressure CO2 System

The SIEX Low Pressure CO2 System uses refrigerated liquid carbon dioxide storage for large hazards requiring substantial agent quantities.

SIEX Low Pressure CO2 System — manufacturer system image
Manufacturer system image. Supplied configuration is defined by the approved product selection.

Product overview

The SIEX Low Pressure CO2 System uses refrigerated liquid carbon dioxide storage for large hazards requiring substantial agent quantities. The manufacturer identifies tank storage from 1 to 60 tonnes, at −20°C and 20 bar. The arrangement can serve total-flooding or local-application designs, with the tank and distribution network selected for the protected hazards.

Technical specifications

Manufacturer SIEX
Product / system Low Pressure CO2 System
Product type Fire Suppression
Product family CO2 Suppression
Subcategory CO2 Systems
Extinguishing agent Carbon dioxide (CO2)
Electrical characteristic Non-conductive agent
Residue No extinguishing residue
Storage temperature −20°C
Storage pressure 20 bar
Published tank storage range 1–60 tonnes
Application arrangements Total flooding / local application

Key features

  • CO2 extinguishing medium
  • Equipment configuration selected for the hazard
  • Manufacturer documentation available

Applications

Industrial and equipment hazards within the approved CO2 system design. Carbon dioxide can create a dangerous atmosphere; personnel exclusion, evacuation, alarms and other required safeguards must be addressed in the engineered installation.

Selection and project integration

Share the protected-space drawings, hazard description, equipment schedule and project specification with UDCT. The technical review should establish the selected system configuration, required quantity, installation constraints and interfaces with the detection and control equipment. For gaseous suppression, enclosure integrity, pressure relief, discharge acoustics and personnel safeguards must be assessed as part of the engineered design.

The published model designation is a product reference, not a final bill of materials. Agent quantities, pipe sizing, nozzle selection, storage arrangements and release logic depend on the approved design. Use the current manufacturer instructions for installation, testing and maintenance, and confirm availability with UDCT before procurement.

Manufacturer documents

Official product reference

View this product on the manufacturer website (opens in a new tab)

START A PROJECT

Discuss this product with UDCT

Send your project specification and required quantities for technical selection and supply support.