Skip to content
SAUDI ARABIA  |  UAE  |  EGYPT
BUILT TO PROTECT ... ENGINEERED TO ENDURE+966122333155

SIEX · Gaseous Suppression

SIEX NC-1230

SIEX NC-1230 is a SIEX total-flooding suppression system using FK-5-1-12.

SIEX SIEX NC-1230 — manufacturer system image
Manufacturer system image. Supplied configuration is defined by the approved product selection.

Product overview

SIEX NC-1230 is a SIEX total-flooding suppression system using FK-5-1-12. The agent and distribution network are selected together for the enclosure and the protected equipment. The system provides a clean extinguishing medium for applications where residue cleanup is an important selection factor. Container arrangement, release interfaces and discharge pipework are engineered for the particular hazard rather than selected from the agent designation alone.

Technical specifications

Manufacturer SIEX
Product / system SIEX NC-1230
Product type Fire Suppression
Product family Gaseous Suppression
Subcategory Chemical Gas / Clean Agent
Extinguishing agent FK-5-1-12
Protection approach Total flooding
Electrical characteristic Non-conductive extinguishing medium
Pressurizing gas Dry nitrogen
Manufacturer-stated certification VdS; confirm exact configuration scope
Storage pressure variants 25 / 42 bar (manufacturer brochure)

Key features

  • Non-conductive clean agent
  • No extinguishing residue after discharge
  • Manufacturer-specific hydraulic calculation method

Applications

Data processing rooms, telecommunications facilities, archives, museums and electrical equipment areas within the approved system design.

Selection and project integration

Share the protected-space drawings, hazard description, equipment schedule and project specification with UDCT. The technical review should establish the selected system configuration, required quantity, installation constraints and interfaces with the detection and control equipment. For gaseous suppression, enclosure integrity, pressure relief, discharge acoustics and personnel safeguards must be assessed as part of the engineered design.

The published model designation is a product reference, not a final bill of materials. Agent quantities, pipe sizing, nozzle selection, storage arrangements and release logic depend on the approved design. Use the current manufacturer instructions for installation, testing and maintenance, and confirm availability with UDCT before procurement.

Manufacturer documents

Official product reference

View this product on the manufacturer website (opens in a new tab)

START A PROJECT

Discuss this product with UDCT

Send your project specification and required quantities for technical selection and supply support.