The TYCO DPV-1 Dry Pipe Valve controls water admission to a dry-pipe sprinkler system when the operating pressure condition is reached.

TYCO DPV-1 Dry Pipe Valve — manufacturer system image
Original manufacturer product/range image. The supplied model, finish, trim and included accessories must match the selected configuration.

Product overview

The TYCO DPV-1 Dry Pipe Valve controls water admission to a dry-pipe sprinkler system when the operating pressure condition is reached. The equipment schedule must identify the exact model, connection size, control or actuation arrangement and any required trim or interface. The technical values below distinguish the published family options; they do not establish that every pressure, size and approval applies to every configuration. Coordinate the selected component with the complete fire-protection system and its commissioning requirements.

Technical specifications

Brand / product range TYCO
Product / system DPV-1 Dry Pipe Valve
Product type Water-Based Systems
Product family Valves & System Components
Subcategory Dry / Deluge / Preaction / Control
Function Differential dry-pipe valve
Maximum working pressure 250 psi (17.2 bar), according to TFP1020
Body construction Ductile iron
Reset External reset without priming water
System supervision Compatible air or nitrogen arrangement; use the required pressure relationship in the installation sheet
Trim Selected pre-trimmed or semi-assembled arrangement; confirm the exact valve connections and accessories
Configuration scope Family and model options shown are not all available in every combination. Select the exact version and its current manufacturer listing.

Key features

  • Function: Differential dry-pipe valve
  • Maximum working pressure: 250 psi (17.2 bar), according to TFP1020
  • Body construction: Ductile iron

Applications

Compatible sprinkler or water-based fire-protection systems requiring the documented control, monitoring or valve function. Confirm system type, operating conditions and the selected component approval before procurement.

Selection and project integration

Provide UDCT with the equipment schedule, exact model or SIN, required connection/size, operating conditions and applicable project specification. Confirm the selected configuration against the current manufacturer document, including compatible components, installation limits and approval scope. Record the chosen part numbers and supplied accessories in the quotation and project submittal.

Manufacturer documents

Official product reference

View this product on the manufacturer website (opens in a new tab)

START A PROJECT

Discuss this product with UDCT

Send your project specification and required quantities for technical selection and supply support.