Product overview
The TYCO FH-1A Flexible Sprinkler Hose provides a flexible connection between a compatible branch line and the selected sprinkler location. The complete assembly includes the specified hose, connection fittings and support arrangement. Choose the model, length, braid option, sprinkler reducer and ceiling bracket together. Hydraulic equivalent length, bend limits and pressure/temperature ratings depend on that combination and the applicable approval table; the published range must not be treated as one universal hose rating.
Technical specifications
| Brand / product range | TYCO |
|---|---|
| Product / system | FH-1A Flexible Sprinkler Hose |
| Product type | Water-Based Systems |
| Product family | Flexible Sprinkler Hose |
| Subcategory | Flexible Drops |
| Product function | FH-1A flexible sprinkler drop assembly |
| Construction | Stainless-steel flexible hose with inlet nipple, sprinkler reducer, bracket, clamps and support bar |
| Styles | Braided or unbraided |
| Nominal lengths in TFP726 | 700, 1000, 1200, 1500 or 1800 mm |
| Inlet connection in TFP726 | 1 inch NPT |
| Outlet options in TFP726 | 1/2 inch or 3/4 inch NPT |
| Maximum service pressure in TFP726 | 13.8 bar, subject to the model/approval tables |
| Maximum ambient temperature in TFP726 | 107°C |
| Bend radius and hydraulic loss | Use the selected model and length table; no common value applies to every assembly |
| Regional selection | Confirm the applicable regional sheet, assembly approvals and bracket configuration before ordering |
| Configuration scope | Family and model options shown are not all available in every combination. Select the exact version and its current manufacturer listing. |
Key features
- Product function: FH-1A flexible sprinkler drop assembly
- Construction: Stainless-steel flexible hose with inlet nipple, sprinkler reducer, bracket, clamps and support bar
- Styles: Braided or unbraided
Applications
Compatible suspended-ceiling sprinkler installations where the documented flexible assembly is permitted. Coordinate the ceiling support, sprinkler location, hydraulic calculation and installation access for the selected configuration.
Selection and project integration
Provide UDCT with the equipment schedule, exact model or SIN, required connection/size, operating conditions and applicable project specification. Confirm the selected configuration against the current manufacturer document, including compatible components, installation limits and approval scope. Record the chosen part numbers and supplied accessories in the quotation and project submittal.
Manufacturer documents
Official product reference
View this product on the manufacturer website (opens in a new tab)