Product overview
The TYCO MLC-S system combines multi-layer composite pipe with the compatible fittings, casting components and installation tools for the documented concrete-ceiling application. The pipe uses metal and plastic layers and is selected as part of a complete approved assembly. The dimensions, pressure and temperature values below describe the referenced pipe component; they must not be applied to unrelated fittings or installation methods. The manufacturer identifies Europe-only availability for this range.
Technical specifications
| Brand / product range | TYCO |
|---|---|
| Product / system | MLC-S Pipe System |
| Product type | Water-Based Systems |
| Product family | Fire Piping |
| Subcategory | Pipe System |
| Sizes | 32 x 3 and 50 x 4.5 (DN25 & DN40) |
| Color | Bright red, as conforming to RAL 3000 |
| Maximum Operating Pressure | 145 psi (10 bar) |
| Maximum Temperature Rating | -10° – 40°C (14° – 104°F) |
| Pipe Length or Size | 50m coils or 5m straight lengths |
| Manufacturer-listed approvals | VdS Approved (no. G 4060066) |
| Configuration scope | Family and model options shown are not all available in every combination. Select the exact version and its current manufacturer listing. |
| Specification scope | Pipe component data from the MLC-S pipe page; complete-system approval also depends on fittings, construction and installation method |
| Manufacturer regional scope | Europe only, as stated on the referenced page |
Approval scope applies to the listed system and component configuration. Confirm the selected equipment against the current manufacturer document and project submittal.
Key features
- Sizes: 32 x 3 and 50 x 4.5 (DN25 & DN40)
- Color: Bright red, as conforming to RAL 3000
- Maximum Operating Pressure: 145 psi (10 bar)
Applications
The documented MLC-S concrete-ceiling sprinkler installation within its manufacturer approval and regional scope. Confirm project acceptance, compatible components and supply availability before considering another market.
Selection and project integration
Provide UDCT with the equipment schedule, exact model or SIN, required connection/size, operating conditions and applicable project specification. Confirm the selected configuration against the current manufacturer document, including compatible components, installation limits and approval scope. Record the chosen part numbers and supplied accessories in the quotation and project submittal.