VES · Fire Detection & Alarm

VES Conventional Manual Pull Stations

The VES conventional manual pull-station range provides non-coded manual alarm or releasing-system inputs in a choice of actions, contact arrangements and reset mechanisms.

VES Conventional Manual Pull Stations — manufacturer system image
Manufacturer image of a VF3046 single-action station. Other actions, contact arrangements and enclosure ratings require separate model selection.

Product overview

The VES conventional manual pull-station range provides non-coded manual alarm or releasing-system inputs in a choice of actions, contact arrangements and reset mechanisms. Select the exact model and suffix to match the circuit and required operating mechanism. Weatherproof and explosion-proof versions have their own model references and must not be treated as general ratings for every station.

Technical specifications

Brand / product range VES
Product / system Conventional Manual Pull Stations
Product type Fire Detection
Product family Fire Detection & Alarm
Subcategory Conventional
Product range Conventional non-coded manual pull stations
Actions Single / dual action, according to selected model
Example single-action models VF3046 / VF3048
Example dual-action models VF3049 / VF3051
Contact options SPST / DPST, according to ordered suffix
Published general contact rating 10 A at 115 V AC; exact variant rating must be confirmed
Construction Die-cast housing and plated steel back switch plate
Reset options Hex-key / Cat 30 key, according to selected model
UL installation temperature 30°F to 150°F
Environmental variants Weatherproof and explosion-proof references are separate model selections, not ratings for the entire range

Key features

  • Product range: Conventional non-coded manual pull stations
  • Actions: Single / dual action, according to selected model
  • Example single-action models: VF3046 / VF3048

Applications

Manual alarm or suppression-release initiation within the specifically selected circuit design and station configuration.

Selection and project integration

Share the fire alarm drawings, equipment schedule, compatible panel platform and cause-and-effect requirements with UDCT. Selection should confirm device protocols, supported interfaces, circuit supervision, power and standby calculations, and the exact enclosure or module arrangement.

Use the current manufacturer documentation to check compatibility, wiring limits, software requirements and approval scope. Commissioning should verify the configured alarm, fault, indication and control functions as part of the complete system. Remote reporting also requires a compatible receiving service and confirmation of local network availability.

Manufacturer documents

Official product reference

View this product on the manufacturer website (opens in a new tab)