Product overview
The PE-6SN and PE-10SN are remote notification-appliance circuit power extenders presented in the VES portfolio. Their 6 A and 10 A versions provide different output-circuit quantities, alongside trigger inputs, trouble relays and a configurable auxiliary output. Synchronization depends on the supported protocol and connected appliance combination. Battery charging capacity and the physical battery space inside the enclosure are separate selection limits.
Technical specifications
| Brand / product range | VES |
|---|---|
| Product / system | PE-6SN / PE-10SN Remote NAC Power Extenders |
| Product type | Fire Detection |
| Product family | Accessories & Power |
| Subcategory | Accessories / Power |
| Models | PE-6SN / PE-10SN |
| AC input | 120 / 240 V AC, 50/60 Hz |
| PE-6SN output | 24 V DC, 6 A maximum; two Class A / four Class B outputs |
| PE-10SN output | 24 V DC, 10 A maximum; three Class A / six Class B outputs |
| Triggers | Two Class A / B trigger circuits |
| Auxiliary output | One programmable output rated 3 A, subject to total supply limits |
| Trouble relays | Two |
| Synchronization protocols | Gentex / System Sensor / Wheelock / Amseco-Potter, compatible appliance and circuit configuration applies |
| Battery charging support | 7–55 Ah, according to sheet |
| Internal battery accommodation | Up to two 12 V DC, 12 Ah batteries |
| Dimensions H x W x D | 16.75 x 16.125 x 3.5 inches |
Key features
- Models: PE-6SN / PE-10SN
- AC input: 120 / 240 V AC, 50/60 Hz
- PE-6SN output: 24 V DC, 6 A maximum; two Class A / four Class B outputs
Applications
Compatible fire alarm power and notification-circuit expansion requiring supervised supplies, calculated load and standby capacity, and the documented circuit arrangements.
Selection and project integration
Share the fire alarm drawings, equipment schedule, compatible panel platform and cause-and-effect requirements with UDCT. Selection should confirm device protocols, supported interfaces, circuit supervision, power and standby calculations, and the exact enclosure or module arrangement.
Use the current manufacturer documentation to check compatibility, wiring limits, software requirements and approval scope. Commissioning should verify the configured alarm, fault, indication and control functions as part of the complete system. Remote reporting also requires a compatible receiving service and confirmation of local network availability.