Product overview
The VES VF2012 Multi-Criteria Sensor uses combined photoelectric smoke sensing and fixed-temperature heat sensing to report conditions to a compatible fire alarm control panel. The detector, mounting base and panel must be selected as a compatible combination, with sensitivity and alarm functions configured for the approved design. The model-specific supply, current and environmental data below supports device selection and loop power calculations. The manufacturer specifies that mounting bases are ordered separately.
Technical specifications
| Brand / product range | VES |
|---|---|
| Product / system | VF2012 Multi-Criteria Sensor |
| Product type | Fire Detection |
| Product family | Fire Detection & Alarm |
| Subcategory | Addressable Initiating Devices |
| Model | VF2012-00 |
| Sensing method | Photoelectric smoke plus thermistor fixed-temperature detection |
| Operating voltage | 17–41 V DC |
| Standby / alarm current | 450 µA / 540 µA |
| Protocol | VES DCP |
| Maximum devices per SLC loop | 127 |
| Fixed heat range | 135°F–150°F, panel configuration applies |
| Operating temperature | 14°F to 122°F |
| Humidity | Up to 95%, non-condensing |
| Smoke sensitivity at 300 FPM | 0.7–4.0% per foot |
| Smoke sensitivity at 2,000 FPM | 0.7–3.86% per foot |
| Smoke sensitivity at 4,000 FPM | 0.7–2.65% per foot |
| Air velocity range | 0–4,000 FPM |
| Weight | 4.2 oz sensor / 5.9 oz with 4 inch base |
| Supply note | Bases are ordered separately; select a compatible listed combination |
Key features
- Model: VF2012-00
- Sensing method: Photoelectric smoke plus thermistor fixed-temperature detection
- Operating voltage: 17–41 V DC
Applications
Compatible addressable installations requiring combined smoke and temperature information, with base and panel compatibility confirmed.
Selection and project integration
Share the fire alarm drawings, equipment schedule, compatible panel platform and cause-and-effect requirements with UDCT. Selection should confirm device protocols, supported interfaces, circuit supervision, power and standby calculations, and the exact enclosure or module arrangement.
Use the current manufacturer documentation to check compatibility, wiring limits, software requirements and approval scope. Commissioning should verify the configured alarm, fault, indication and control functions as part of the complete system. Remote reporting also requires a compatible receiving service and confirmation of local network availability.