VES VF2045 / VF2046 Conventional Photoelectric Smoke / Smoke-Heat Detector

The VES VF2045 and VF2046 are conventional multi-spectrum photoelectric detectors using infrared and blue light to evaluate smoke characteristics.

VES VF2045 / VF2046 Conventional Photoelectric Smoke / Smoke-Heat Detector — manufacturer system image
Manufacturer image of VF2046 with heat sensing. VF2045 is the smoke-only version and has a different height.

Product overview

The VES VF2045 and VF2046 are conventional multi-spectrum photoelectric detectors using infrared and blue light to evaluate smoke characteristics. The VF2046 additionally includes thermistor heat detection, while the VF2045 is the smoke-only version. Both require a compatible listed detector-base and control-panel arrangement. Selection must distinguish the heat function, physical height, circuit current limits and approved operating conditions for the exact model.

Technical specifications

Manufacturer Kentec Electronics Ltd.
Brand / product range VES
Product / system VF2045 / VF2046 Conventional Photoelectric Smoke / Smoke-Heat Detector
Product type Fire Detection
Product family Fire Detection & Alarm
Subcategory Conventional
Models VF2045-00 smoke / VF2046-00 smoke and heat
Sensing method IR and blue light photoelectric sensing; thermistor on VF2046 only
Operating / absolute maximum voltage 8–35 V DC / 42 V DC
Standby current 59 µA
Permitted alarm current 5–150 mA, manufacturer circuit conditions apply
Smoke sensitivity 1.50–3.50% per foot in documented open-area / duct conditions
VF2046 heat threshold 135°F or 20°F per minute rise, whichever occurs first
Compatible bases VF2050-00 / VF2051-00
Operating temperature 32°F to 120°F
Humidity limit Less than 95% RH at 104°F / less than 80% RH at 120°F
Dimensions 3.94 inch diameter; VF2045 height 1.77 inches / VF2046 height 2.18 inches
Weight 3.4 oz
Colour Ivory
Manufacturer-listed approvals UL 268, 7th edition, stated in sheet; separate pending marks are also present, so confirm current exact approval scope

Approval scope applies to the listed system and component configuration. Confirm the selected equipment against the current manufacturer document and project submittal.

Key features

  • Models: VF2045-00 smoke / VF2046-00 smoke and heat
  • Sensing method: IR and blue light photoelectric sensing; thermistor on VF2046 only
  • Operating / absolute maximum voltage: 8–35 V DC / 42 V DC

Applications

Conventional fire alarm installations using the documented VF2050 or VF2051 base and compatible panel. Select smoke-only or combined smoke-and-heat detection according to the approved strategy.

Selection and project integration

Share the fire alarm drawings, equipment schedule, compatible panel platform and cause-and-effect requirements with UDCT. Selection should confirm device protocols, supported interfaces, circuit supervision, power and standby calculations, and the exact enclosure or module arrangement.

Use the current manufacturer documentation to check compatibility, wiring limits, software requirements and approval scope. Commissioning should verify the configured alarm, fault, indication and control functions as part of the complete system. Remote reporting also requires a compatible receiving service and confirmation of local network availability.

Manufacturer documents

Official product reference

View this product on the manufacturer website (opens in a new tab)

START A PROJECT

Discuss this product with UDCT

Send your project specification and required quantities for technical selection and supply support.