Product overview
The VES VF4000-X0 Low-Profile Horn is an indoor wall-mounted horn without a strobe. Select the exact mounting format and supported output settings for the approved notification design. The supply waveform, selected sound pattern or candela setting, synchronization interface and circuit load determine the permitted installation. This product is not presented as an outdoor appliance.
Technical specifications
| Brand / product range | VES |
|---|---|
| Product / system | VF4000-X0 Low-Profile Horn |
| Product type | Fire Detection |
| Product family | Notification Appliances |
| Subcategory | Notification |
| Models | VF4000-10 red / VF4000-30 off-white |
| Appliance | Wall-mounted horn, without strobe |
| Nominal supply / operating range | 24 V DC / 16–33 V DC or documented FWR supply |
| Tones | 2,400 Hz / mechanical / chime / whoop, selected configuration applies |
| Patterns | Continuous / Temporal 3; whoop does not support Temporal 3 |
| Output selection | High / low dBA, with public/private-mode restrictions in the manufacturer sheet |
| Dimensions H x W x D | 5 x 4.5 x 2.5 inches |
| Terminals | 12–18 AWG |
| Operating temperature | 0°C to +49°C |
| Environment | Indoor only; not listed for outdoor use |
| Circuit current | Tone-dependent; use manufacturer horn-current table |
| Manufacturer-listed approvals | UL 464 and FM scope for the exact horn configuration must be confirmed |
Approval scope applies to the listed system and component configuration. Confirm the selected equipment against the current manufacturer document and project submittal.
Key features
- Models: VF4000-10 red / VF4000-30 off-white
- Appliance: Wall-mounted horn, without strobe
- Nominal supply / operating range: 24 V DC / 16–33 V DC or documented FWR supply
Applications
Indoor fire alarm notification within the exact model listing, with sound or visual coverage, accessibility requirements, synchronization and circuit power calculated for the project.
Selection and project integration
Share the fire alarm drawings, equipment schedule, compatible panel platform and cause-and-effect requirements with UDCT. Selection should confirm device protocols, supported interfaces, circuit supervision, power and standby calculations, and the exact enclosure or module arrangement.
Use the current manufacturer documentation to check compatibility, wiring limits, software requirements and approval scope. Commissioning should verify the configured alarm, fault, indication and control functions as part of the complete system. Remote reporting also requires a compatible receiving service and confirmation of local network availability.