Product overview
The VES VF5601 Discovery photoelectric smoke sensor uses an infrared emitter and optical chamber to measure light scattered by smoke. A compatible fire alarm panel receives the processed value and applies the configured response. Five operating modes and drift compensation support the selected detection strategy. The location address remains with the XPERT card in the base, so replacement of a compatible head does not itself require changing the location address.
Technical specifications
| Brand / product range | VES |
|---|---|
| Product / system | VF5601 Discovery Photoelectric Detector |
| Product type | Fire Detection |
| Product family | Fire Detection & Alarm |
| Subcategory | Apollo Addressable |
| Model | VF5601-00 |
| Detection principle | Infrared light-scatter photoelectric smoke sensing |
| Compatible panel family | Elite / Elite RS with the documented Apollo-protocol configuration |
| Operating modes | Five selectable response modes |
| Compensation | Automatic sensor-drift compensation |
| Addressing | XPERT card retained in the base |
| Operating voltage | 17–28 V DC |
| Standby current | 400 µA |
| Alarm current | 3.4 mA |
| Continuous operating temperature | 32°F to 140°F |
| Minimum operating temperature | −4°F only without condensation or icing |
| Dimensions | 3.93 inch diameter x 1.65 inch high; 1.96 inch in base |
| Detector weight | 3.68 oz |
| Indicators | Two status LEDs |
| Accessories | Compatible base and address card ordered separately |
Key features
- Model: VF5601-00
- Detection principle: Infrared light-scatter photoelectric smoke sensing
- Compatible panel family: Elite / Elite RS with the documented Apollo-protocol configuration
Applications
Photoelectric smoke detection on compatible addressable systems. Select the response mode, spacing and installation conditions for the expected smoke characteristics and normal environment.
Selection and project integration
Share the fire alarm drawings, equipment schedule, compatible panel platform and cause-and-effect requirements with UDCT. Selection should confirm device protocols, supported interfaces, circuit supervision, power and standby calculations, and the exact enclosure or module arrangement.
Use the current manufacturer documentation to check compatibility, wiring limits, software requirements and approval scope. Commissioning should verify the configured alarm, fault, indication and control functions as part of the complete system. Remote reporting also requires a compatible receiving service and confirmation of local network availability.