VES VF5664-00 VES95A Dual Priority Switch Monitor

The VES VF5664 VES95A dual priority switch monitor provides two contact-monitoring inputs on one module.

VES VF5664-00 VES95A Dual Priority Switch Monitor — manufacturer system image
Original VF5664 dual-input module board image from VES. The electrical mounting box is selected separately.

Product overview

The VES VF5664 VES95A dual priority switch monitor provides two contact-monitoring inputs on one module. It reports the documented input states and supports Class A or Class B field-wiring arrangements. The module is polarity sensitive, and current consumption depends on the input and LED condition. Select the compatible panel, input configuration, end-of-line components and metal mounting box as part of the complete installation.

Technical specifications

Brand / product range VES
Product / system VF5664-00 VES95A Dual Priority Switch Monitor
Product type Fire Detection
Product family Fire Detection & Alarm
Subcategory Apollo Modules
Model VF5664-00
Function Dual priority switch monitor
Inputs Two individual voltage-free contact inputs
Input states Normal, fault and alarm
Wiring configuration Class A or Class B inputs
Polarity Polarity sensitive; L1 negative and L2 positive in the referenced instructions
Current measurement basis At 24 V
Switch-on surge 2.5 mA, maximum 65 milliseconds
Quiescent current 1.5 mA with 47 kΩ end-of-line resistance fitted
Alarm current with LED 10 mA
Input short-circuit current 6 mA
Indicators Two LEDs
Mounting Suitable two-gang or 4 inch electrical box; box supplied separately
Wiring supervision Power limited and supervised as stated in the sheet

Key features

  • Model: VF5664-00
  • Function: Dual priority switch monitor
  • Inputs: Two individual voltage-free contact inputs

Applications

Compatible addressable designs needing two independent contact-monitoring channels with priority response. Confirm the programmed input functions and wiring supervision for the connected devices.

Selection and project integration

Share the fire alarm drawings, equipment schedule, compatible panel platform and cause-and-effect requirements with UDCT. Selection should confirm device protocols, supported interfaces, circuit supervision, power and standby calculations, and the exact enclosure or module arrangement.

Use the current manufacturer documentation to check compatibility, wiring limits, software requirements and approval scope. Commissioning should verify the configured alarm, fault, indication and control functions as part of the complete system. Remote reporting also requires a compatible receiving service and confirmation of local network availability.

Manufacturer documents

Official product reference

View this product on the manufacturer website (opens in a new tab)

START A PROJECT

Discuss this product with UDCT

Send your project specification and required quantities for technical selection and supply support.