Product overview
The VES VF5664 VES95A dual priority switch monitor provides two contact-monitoring inputs on one module. It reports the documented input states and supports Class A or Class B field-wiring arrangements. The module is polarity sensitive, and current consumption depends on the input and LED condition. Select the compatible panel, input configuration, end-of-line components and metal mounting box as part of the complete installation.
Technical specifications
| Brand / product range | VES |
|---|---|
| Product / system | VF5664-00 VES95A Dual Priority Switch Monitor |
| Product type | Fire Detection |
| Product family | Fire Detection & Alarm |
| Subcategory | Apollo Modules |
| Model | VF5664-00 |
| Function | Dual priority switch monitor |
| Inputs | Two individual voltage-free contact inputs |
| Input states | Normal, fault and alarm |
| Wiring configuration | Class A or Class B inputs |
| Polarity | Polarity sensitive; L1 negative and L2 positive in the referenced instructions |
| Current measurement basis | At 24 V |
| Switch-on surge | 2.5 mA, maximum 65 milliseconds |
| Quiescent current | 1.5 mA with 47 kΩ end-of-line resistance fitted |
| Alarm current with LED | 10 mA |
| Input short-circuit current | 6 mA |
| Indicators | Two LEDs |
| Mounting | Suitable two-gang or 4 inch electrical box; box supplied separately |
| Wiring supervision | Power limited and supervised as stated in the sheet |
Key features
- Model: VF5664-00
- Function: Dual priority switch monitor
- Inputs: Two individual voltage-free contact inputs
Applications
Compatible addressable designs needing two independent contact-monitoring channels with priority response. Confirm the programmed input functions and wiring supervision for the connected devices.
Selection and project integration
Share the fire alarm drawings, equipment schedule, compatible panel platform and cause-and-effect requirements with UDCT. Selection should confirm device protocols, supported interfaces, circuit supervision, power and standby calculations, and the exact enclosure or module arrangement.
Use the current manufacturer documentation to check compatibility, wiring limits, software requirements and approval scope. Commissioning should verify the configured alarm, fault, indication and control functions as part of the complete system. Remote reporting also requires a compatible receiving service and confirmation of local network availability.
Manufacturer documents