VES · Fire Detection & Alarm

VES VF5667-00 VES95A Relay Output Module

The VES VF5667 VES95A relay output module provides a dual Form C voltage-free switching interface controlled by compatible fire alarm equipment.

VES VF5667-00 VES95A Relay Output Module — manufacturer system image
Original VF5667 relay module board image from the matching VES sheet. Confirm the relay contact rating and mounting assembly before specifying a load.

Product overview

The VES VF5667 VES95A relay output module provides a dual Form C voltage-free switching interface controlled by compatible fire alarm equipment. It uses loop power and includes a status LED that indicates polling and the configured active state. The selected contact duty must be checked against the full installation documentation because the linked summary sheet does not publish a relay-load rating. Coordinate the interface with the approved cause-and-effect schedule and the requirements of the connected equipment.

Technical specifications

Brand / product range VES
Product / system VF5667-00 VES95A Relay Output Module
Product type Fire Detection
Product family Fire Detection & Alarm
Subcategory Apollo Modules
Model VF5667-00
Function Dual Form C voltage-free relay output
Power Loop powered
Working voltage 17–28 V DC
Modulation voltage 5–9 V peak to peak
Supervisory current 0.85 mA
Surge current 2.5 mA
Maximum alarm current 3.5 mA
Dimensions 4.5 x 4.5 x 1 inches
Mounting Two-gang or 4 inch square electrical box
Temperature 32°F to 120°F
Humidity 10–93%, non-condensing
Indicator One red LED with polling / configured active-state indication
Contact-load selection The linked summary sheet does not state a contact-load rating; obtain the installation instructions and confirm the connected load before selection

Key features

  • Model: VF5667-00
  • Function: Dual Form C voltage-free relay output
  • Power: Loop powered

Applications

Configured ancillary switching interfaces in compatible addressable systems, after confirming contact ratings, permitted use and any required supervision for the connected equipment.

Selection and project integration

Share the fire alarm drawings, equipment schedule, compatible panel platform and cause-and-effect requirements with UDCT. Selection should confirm device protocols, supported interfaces, circuit supervision, power and standby calculations, and the exact enclosure or module arrangement.

Use the current manufacturer documentation to check compatibility, wiring limits, software requirements and approval scope. Commissioning should verify the configured alarm, fault, indication and control functions as part of the complete system. Remote reporting also requires a compatible receiving service and confirmation of local network availability.

Manufacturer documents

Official product reference

View this product on the manufacturer website (opens in a new tab)