VES · Fire Detection & Alarm

VES VF6002 / VF6013 Fast Response Contact Module

The VES VF6002 / VF6013 Fast Response Contact Module monitors a dry-contact input using the VES DCP loop.

VES VF6002 / VF6013 Fast Response Contact Module — manufacturer system image
Manufacturer image of the compact VF6013 contact module. The VF6002 uses a different mounting arrangement and has a visible status LED.

Product overview

The VES VF6002 / VF6013 Fast Response Contact Module monitors a dry-contact input using the VES DCP loop. Its circuit role and electrical limits must be coordinated with the compatible panel and approved fire alarm design. The model-specific data below distinguishes the interface configuration, supply requirements and installation conditions so the exact version can be selected for the project.

Technical specifications

Manufacturer VES
Product / system VF6002 / VF6013 Fast Response Contact Module
Product type Fire Detection
Product family Fire Detection & Alarm
Subcategory Addressable Modules
Models VF6002-00 / VF6013-00
Input One dry-contact monitoring circuit; NO or NC configuration
Protocol VES DCP
Loop operating voltage 17–41 V DC
Typical average current 550 µA
Alarm current 30 mA
Maximum devices per loop 127
VF6002 dimensions W x H x D 4.2 x 4.7 x 1.4 inches
VF6013 dimensions W x H x D 2.8 x 1.8 x 0.7 inches
Indication Visible bi-colour status LED on VF6002 only
UL installation temperature 32°F to 120°F
Humidity 90% RH, non-condensing

Key features

  • Models: VF6002-00 / VF6013-00
  • Input: One dry-contact monitoring circuit; NO or NC configuration
  • Protocol: VES DCP

Applications

Dry-contact monitoring of compatible initiating devices such as pull stations or water-flow switches.

Selection and project integration

Share the fire alarm drawings, equipment schedule, compatible panel platform and cause-and-effect requirements with UDCT. Selection should confirm device protocols, supported interfaces, circuit supervision, power and standby calculations, and the exact enclosure or module arrangement.

Use the current manufacturer documentation to check compatibility, wiring limits, software requirements and approval scope. Commissioning should verify the configured alarm, fault, indication and control functions as part of the complete system. Remote reporting also requires a compatible receiving service and confirmation of local network availability.