VES · Fire Detection & Alarm

VES VF6007 Dual Input Monitor

The VES VF6007 Dual Input Monitor monitors two independent contact inputs while using one SLC address.

VES VF6007 Dual Input Monitor — manufacturer system image
Manufacturer system image. Supplied configuration is defined by the approved product selection.

Product overview

The VES VF6007 Dual Input Monitor monitors two independent contact inputs while using one SLC address. Its circuit role and electrical limits must be coordinated with the compatible panel and approved fire alarm design. The model-specific data below distinguishes the interface configuration, supply requirements and installation conditions so the exact version can be selected for the project.

Technical specifications

Manufacturer VES
Product / system VF6007 Dual Input Monitor
Product type Fire Detection
Product family Fire Detection & Alarm
Subcategory Addressable Modules
Model VF6007-00
Protocol VES DCP; Elite analogue addressable system
Inputs Two independent NO / NC contact-monitoring circuits
Address usage One SLC address for two inputs
Maximum devices per loop 127
Operating voltage 17–41 V DC
Typical average current 600 µA
Alarm current 30 mA
Mounting 4 inch square electrical box
Dimensions W x H x D 4.2 x 4.7 x 1.4 inches
UL installation temperature 32°F to 120°F
Humidity Up to 90%, non-condensing

Key features

  • Model: VF6007-00
  • Protocol: VES DCP; Elite analogue addressable system
  • Inputs: Two independent NO / NC contact-monitoring circuits

Applications

Monitoring nearby dry-contact alarm and supervisory devices, such as water-flow and valve-supervision inputs, on a compatible Elite system.

Selection and project integration

Share the fire alarm drawings, equipment schedule, compatible panel platform and cause-and-effect requirements with UDCT. Selection should confirm device protocols, supported interfaces, circuit supervision, power and standby calculations, and the exact enclosure or module arrangement.

Use the current manufacturer documentation to check compatibility, wiring limits, software requirements and approval scope. Commissioning should verify the configured alarm, fault, indication and control functions as part of the complete system. Remote reporting also requires a compatible receiving service and confirmation of local network availability.