VES VF7005 / VF7006 Low Frequency Sounder Base / Trim

The VES VF7005 / VF7006 Low Frequency Sounder Base / Trim combines a compatible sensor mounting arrangement with local audible alarm indication.

VES VF7005 / VF7006 Low Frequency Sounder Base / Trim — manufacturer system image
Original equipment image from the matching VES technical sheet. The selected model, compatible sensor and any optional accessories are defined by the quotation.

Product overview

The VES VF7005 / VF7006 Low Frequency Sounder Base / Trim combines a compatible sensor mounting arrangement with local audible alarm indication. The documented 520 Hz output is intended for applications requiring a low-frequency alarm signal. The base obtains its addressing relationship from the attached sensor, while an auxiliary supply provides sounder power. Selection must account for detector compatibility, loop quantity, auxiliary current, voltage drop and the permitted operating environment.

Technical specifications

Brand / product range VES
Product / system VF7005 / VF7006 Low Frequency Sounder Base / Trim
Product type Fire Detection
Product family Fire Detection & Alarm
Subcategory Addressable Initiating Devices
Models VF7005-00 sounder base / VF7006-00 optional trim ring
Sounder frequency 520 Hz
Sound pressure level 85 dB at 10 ft, as stated in sheet
Operating loop voltage 17–41 V DC
SLC idle / alarm current 154 µA / 154 µA
Auxiliary voltage range 16–31 V DC, as stated in specification
Auxiliary idle current 2.8 mA
Auxiliary alarm current at 24 V DC 95 mA; supply waveform changes current demand
Maximum bases per SLC loop 127
Patterns Continuous / March / ANSI Temporal 3 and 4, configured with compatible system
CO pattern support Temporal 4 with VF2014 CO detector, according to sheet
Operating temperature 32°F to 122°F
UL installation temperature 32°F to 100°F
Humidity Up to 93%, non-condensing
Base dimensions 6.6 inch diameter x 3.1 inch height
Approval note Sheet states UL 268 / UL 464 listing and includes a separate pending approval mark; confirm exact current approval scope
Listed sensor references VF2001, VF2002, VF2003, VF2005, VF2008, VF2010, VF2011, VF2012, VF2014

Key features

  • Models: VF7005-00 sounder base / VF7006-00 optional trim ring
  • Sounder frequency: 520 Hz
  • Sound pressure level: 85 dB at 10 ft, as stated in sheet

Applications

Local audible indication in compatible hotel, apartment and hospital fire alarm designs. Verify sound coverage, required alarm pattern and the listed sensor/base combination for the project.

Selection and project integration

Share the fire alarm drawings, equipment schedule, compatible panel platform and cause-and-effect requirements with UDCT. Selection should confirm device protocols, supported interfaces, circuit supervision, power and standby calculations, and the exact enclosure or module arrangement.

Use the current manufacturer documentation to check compatibility, wiring limits, software requirements and approval scope. Commissioning should verify the configured alarm, fault, indication and control functions as part of the complete system. Remote reporting also requires a compatible receiving service and confirmation of local network availability.

Manufacturer documents

Official product reference

View this product on the manufacturer website (opens in a new tab)