Skip to content
SAUDI ARABIA  |  UAE  |  EGYPT
BUILT TO PROTECT ... ENGINEERED TO ENDURE+966122333155

VES · Fire Detection & Alarm

VES VF7015 / VF7016 Updated Base with Isolator

The VES VF7015 / VF7016 Updated Base with Isolator provides the mounting and electrical connection for the compatible analogue sensor models listed in the technical data.

VES VF7015 / VF7016 Updated Base with Isolator — manufacturer system image
Original equipment image from the matching VES technical sheet. The selected model, compatible sensor and any optional accessories are defined by the quotation.

Product overview

The VES VF7015 / VF7016 Updated Base with Isolator provides the mounting and electrical connection for the compatible analogue sensor models listed in the technical data. This version includes a short-circuit isolator and fault indication, so loop topology and isolation requirements form part of selection. The updated range explicitly includes VF2015 compatibility in the referenced sheet. Choose the 4 inch or 6 inch version, mounting arrangement and optional tamper-lock feature to suit the installation.

Technical specifications

Brand / product range VES
Product / system VF7015 / VF7016 Updated Base with Isolator
Product type Fire Detection
Product family Fire Detection & Alarm
Subcategory Addressable Initiating Devices
Models VF7015-00: 4 inch / VF7016-00: 6 inch
Base type Updated analogue sensor base with integrated short-circuit isolator
Operating voltage 17–41 V DC
Normal / active current 160 µA / 10 mA
Listed sensor references VF2001, VF2002, VF2003, VF2005, VF2008, VF2010, VF2011, VF2012, VF2014, VF2015
Short-circuit indication Built-in LED
SLC maximum resistance 50 ohms
Security feature Optional plastic tamper-lock tab
Material / colour Bone PC / ABS blend
Manufacturer-listed approvals UL Listed; referenced February 2024 design includes VF2015 compatibility

Approval scope applies to the listed system and component configuration. Confirm the selected equipment against the current manufacturer document and project submittal.

Key features

  • Models: VF7015-00: 4 inch / VF7016-00: 6 inch
  • Base type: Updated analogue sensor base with integrated short-circuit isolator
  • Operating voltage: 17–41 V DC

Applications

Mounting and wiring of the specifically listed VES analogue sensors within a compatible fire alarm system. Confirm the exact detector/base combination and enclosure requirements before procurement.

Selection and project integration

Share the fire alarm drawings, equipment schedule, compatible panel platform and cause-and-effect requirements with UDCT. Selection should confirm device protocols, supported interfaces, circuit supervision, power and standby calculations, and the exact enclosure or module arrangement.

Use the current manufacturer documentation to check compatibility, wiring limits, software requirements and approval scope. Commissioning should verify the configured alarm, fault, indication and control functions as part of the complete system. Remote reporting also requires a compatible receiving service and confirmation of local network availability.

Manufacturer documents

Official product reference

View this product on the manufacturer website (opens in a new tab)

START A PROJECT

Discuss this product with UDCT

Send your project specification and required quantities for technical selection and supply support.