Product overview
The VES VF7018 6 in Analog Sounder Base combines a compatible sensor mounting arrangement with local audible alarm indication. Configured alarm patterns support coordinated audible indication near the installed sensor. The base obtains its addressing relationship from the attached sensor, while an auxiliary supply provides sounder power. Selection must account for detector compatibility, loop quantity, auxiliary current, voltage drop and the permitted operating environment.
Technical specifications
| Brand / product range | VES |
|---|---|
| Product / system | VF7018 6 in Analog Sounder Base |
| Product type | Fire Detection |
| Product family | Fire Detection & Alarm |
| Subcategory | Addressable Initiating Devices |
| Model | VF7018-00 |
| Base type | Updated 6 inch analogue sounder base |
| Listed sensor references | VF2001, VF2002, VF2003, VF2005, VF2008, VF2010, VF2011, VF2012, VF2014, VF2015 |
| Loop operating voltage | 17–41 V DC |
| SLC idle / alarm current | 170 µA / 170 µA |
| Auxiliary supply | 16–31 V DC |
| Auxiliary idle / alarm current | 550 µA / 18 mA |
| Maximum bases per loop | 127, subject to supply and wiring limits |
| Sound pressure level | 85 dB at 10 ft |
| Alarm patterns | Continuous / March / ANSI Temporal 3, compatible programming applies |
| Dimensions | 5.9 inch diameter x 1.3 inch height |
| Weight | 0.455 lb |
| Operating / UL installation temperature | 32°F to 100°F |
| Humidity | Up to 93%, non-condensing |
| Manufacturer-listed approvals | UL Listed, selected detector/base configuration applies |
Approval scope applies to the listed system and component configuration. Confirm the selected equipment against the current manufacturer document and project submittal.
Key features
- Model: VF7018-00
- Base type: Updated 6 inch analogue sounder base
- Listed sensor references: VF2001, VF2002, VF2003, VF2005, VF2008, VF2010, VF2011, VF2012, VF2014, VF2015
Applications
Local audible indication in compatible hotel, apartment and hospital fire alarm designs. Verify sound coverage, required alarm pattern and the listed sensor/base combination for the project.
Selection and project integration
Share the fire alarm drawings, equipment schedule, compatible panel platform and cause-and-effect requirements with UDCT. Selection should confirm device protocols, supported interfaces, circuit supervision, power and standby calculations, and the exact enclosure or module arrangement.
Use the current manufacturer documentation to check compatibility, wiring limits, software requirements and approval scope. Commissioning should verify the configured alarm, fault, indication and control functions as part of the complete system. Remote reporting also requires a compatible receiving service and confirmation of local network availability.
Manufacturer documents
Official product reference
View this product on the manufacturer website (opens in a new tab)