Product overview
The Vizulinx gateway provides supplementary remote monitoring and building-management integration for compatible VES fire alarm systems. Its embedded web interface supports configuration of the permitted status and interface functions. Modbus IP and BACnet IP availability depends on the connected panel and purchased licence scope; the referenced sheet limits BACnet support to Latitude and Compas. Vizulinx is not a primary fire-notification system.
Technical specifications
| Brand / product range | VES |
|---|---|
| Product / system | Vizulinx Gateway K85000 / K85000M2 / K85110AM3 / K85240AM3 |
| Product type | Fire Detection |
| Product family | Fire Detection & Alarm |
| Subcategory | Addressable Control Panels / Network |
| Models | K85000 module / K85000M2 / K85110AM3 / K85240AM3 housed arrangements |
| Purpose | Supplementary monitoring and BMS integration gateway; not primary fire notification |
| Module supply | 9–30 V DC |
| Module current at 24 V DC | 97 mA, as stated in sheet |
| Integration protocols | Modbus IP / BACnet IP |
| BACnet panel scope | VES Latitude / Compas only, according to referenced sheet |
| Panel connections | IP / serial / GPIO, compatibility depends on panel |
| Configuration | Embedded web server and EZ configuration feature |
| Ethernet ports | Two |
| Included Modbus points | 500 panel / 500 zone / 1,000 loop-device addresses |
| Expansion | Optional protocol-specific address / object licences; configured limits apply |
| Housed selection | Confirm exact mains supply, battery and enclosure configuration for ordered variant |
Key features
- Models: K85000 module / K85000M2 / K85110AM3 / K85240AM3 housed arrangements
- Purpose: Supplementary monitoring and BMS integration gateway; not primary fire notification
- Module supply: 9–30 V DC
Applications
Supplementary BMS integration and diagnostic monitoring where the exact VES panel, interface method, network design and protocol licence are supported.
Selection and project integration
Share the fire alarm drawings, equipment schedule, compatible panel platform and cause-and-effect requirements with UDCT. Selection should confirm device protocols, supported interfaces, circuit supervision, power and standby calculations, and the exact enclosure or module arrangement.
Use the current manufacturer documentation to check compatibility, wiring limits, software requirements and approval scope. Commissioning should verify the configured alarm, fault, indication and control functions as part of the complete system. Remote reporting also requires a compatible receiving service and confirmation of local network availability.