VES · Voice Evacuation

VES VoiceAlert 50 W / 100 W System

The VES VoiceAlert 50 W / 100 W System provides a range of voice-evacuation amplifier panels with an integral microphone, recorded-message facility, power supply and battery charger.

VES VoiceAlert 50 W / 100 W System — manufacturer system image
Original VoiceAlert system image from the matching VES sheet. The exact amplifier, zone and cabinet configuration is defined by the selected model.

Product overview

The VES VoiceAlert 50 W / 100 W System provides a range of voice-evacuation amplifier panels with an integral microphone, recorded-message facility, power supply and battery charger. The selected model determines the total audio power and speaker-zone arrangement. Confirm the speaker voltage, connected load, alarm zoning and supported fire alarm interface together with the project message strategy and standby-power calculation.

Technical specifications

Brand / product range VES
Product / system VoiceAlert 50 W / 100 W System
Product type Fire Detection
Product family Voice Evacuation
Subcategory Voice Evacuation
Model families VF922x: 50 W / VF924x: 100 W
Speaker output voltage Field-selectable 25 / 70 V RMS
Primary supply 120 V AC, with power supply and battery charger
Message capacity Up to four minutes
Controls Integral live paging microphone with message / tone override
Zone model options Base system / four / eight / twelve / sixteen speaker zones
FACP interface Compatible 12 V DC / 24 V DC fire alarm panel
Enclosure colours Red suffix -10 / charcoal suffix -20
Standby selection Battery capacity and standby duration require system load calculation

Key features

  • Model families: VF922x: 50 W / VF924x: 100 W
  • Speaker output voltage: Field-selectable 25 / 70 V RMS
  • Primary supply: 120 V AC, with power supply and battery charger

Applications

Compatible voice-evacuation installations requiring the selected amplifier capacity and speaker zoning, with sound coverage and intelligibility established by the project design.

Selection and project integration

Share the fire alarm drawings, equipment schedule, compatible panel platform and cause-and-effect requirements with UDCT. Selection should confirm device protocols, supported interfaces, circuit supervision, power and standby calculations, and the exact enclosure or module arrangement.

Use the current manufacturer documentation to check compatibility, wiring limits, software requirements and approval scope. Commissioning should verify the configured alarm, fault, indication and control functions as part of the complete system. Remote reporting also requires a compatible receiving service and confirmation of local network availability.

Manufacturer documents

Official product reference

View this product on the manufacturer website (opens in a new tab)

START A PROJECT

Discuss this product with UDCT

Send your project specification and required quantities for technical selection and supply support.