VIKING · Storage Sprinklers

VIKING VK500 ESFR Pendent Sprinkler

The VK500 uses a fusible element and a special deflector to produce large water droplets for early suppression in specified high-challenge storage arrangements.

Viking VK500 ESFR pendent storage sprinkler
Manufacturer system image. Supplied configuration is defined by the approved product selection.

Product overview

The VK500 uses a fusible element and a special deflector to produce large water droplets for early suppression in specified high-challenge storage arrangements. The model is a fast-response pendent sprinkler with a maximum working pressure of 175 psi (12 bar). Product selection must follow Viking's current technical data sheet, approved storage configuration, water supply and the authority having jurisdiction.

Technical specifications

Manufacturer The Viking Corporation
Brand / product range VIKING
Product / system VK500 ESFR Pendent Sprinkler
Product type Sprinklers & Valves
Product family Storage Sprinklers
Subcategory Early Suppression Fast Response (ESFR)
Model VK500
Nominal K-factor 14.0 (202 metric)
Manufacturer part numbers 10284, 21360, 27393
Response Fast (ESFR)
Orientation Pendent
Operating element Fusible element
Maximum working pressure 175 psi (12 bar)
Connection 3/4 in NPT (20 mm BSP)
Application class Storage, subject to listed design criteria

Key features

  • Early Suppression Fast Response performance for listed storage hazards
  • Model-specific 14.0 (202 metric) nominal K-factor
  • Manufacturer technical data and approval information available for project submittal

Applications

Engineered warehouse and high-piled storage fire protection. Commodity, storage height, ceiling height, clearance, aisle layout and water demand must be checked against the model-specific Viking data sheet and the relevant listing.

Selection and project integration

Specify model VK500, the required temperature rating and finish, sprinkler orientation, water supply, storage geometry and authority requirements. Do not substitute another ESFR model by K-factor alone; verify the current manufacturer data sheet and approved design criteria before ordering.

Manufacturer documents

Official product reference

View this product on the manufacturer website (opens in a new tab)

START A PROJECT

Discuss this product with UDCT